Fire Safety Plans & Approvals

Most buildings beyond a house — apartments, offices, retail, industrial, assembly and care occupancies — are required by their provincial fire code to have a fire safety plan approved by the local fire department, kept on site, reviewed regularly and actually implemented through trained staff. Many buildings either have none, or a decades-old binder nobody has opened.

What a compliant plan contains

Emergency procedures for occupants and staff, the audibility and control features of the alarm system, designated supervisory staff and their training, fire drill frequency, maintenance schedules for every fire protection system in the building, schematic drawings, and provisions for occupants requiring assistance. It must reflect the building as it exists — renovations, use changes and staffing changes all trigger updates.

Approval and implementation

The plan is submitted to the fire department having jurisdiction for approval, and the approved copy kept at the premises — typically at the annunciator or a fire safety plan box. Approval is not the end: the code requires drills (from annual in offices to monthly in care occupancies), staff instruction, and keeping the plan current with at least annual review.

Where owners get caught

Plan deficiencies surface after incidents and during routine inspections — a missing plan is an immediate order, and an inaccurate one (wrong staff, wrong systems, outdated drawings) can be worse than none in litigation after a fire.

How the process works

  1. Send us the building profile — occupancy, storeys, systems — and any existing plan.
  2. A fire safety planning consultant drafts or updates the plan to your province’s template.
  3. Drawings are produced or updated from a site walk-through.
  4. The plan is submitted to your fire department and revised to approval.
  5. Optional: warden training, drill facilitation and the annual review cycle.

Who regulates this in each province

Province / TerritoryGoverning codeKey authority
OntarioOntario Fire Code (O. Reg. 213/07)the Office of the Fire Marshal and your local fire service
QuebecQuebec Safety Code (Chapter VIII, Building)Régie du bâtiment du Québec (RBQ)
British ColumbiaBC Fire Codethe provincial fire marshal’s office and your local fire service
AlbertaNational Fire Code (Alberta Edition)the provincial fire marshal’s office and your local fire service
ManitobaManitoba Fire Codethe provincial fire marshal’s office and your local fire service
SaskatchewanNational Fire Code as adopted in Saskatchewanthe provincial fire marshal’s office and your local fire service
Nova ScotiaNova Scotia Fire Safety Regulationsthe provincial fire marshal’s office and your local fire service
New BrunswickNational Fire Code as adopted by the Office of the Fire Marshalthe provincial fire marshal’s office and your local fire service
Newfoundland and LabradorFire Protection Services Act and adopted National Fire Codethe provincial fire marshal’s office and your local fire service
Prince Edward IslandFire Prevention Act and adopted National Fire Codethe provincial fire marshal’s office and your local fire service
YukonNational Fire Code as enforced by the Yukon Fire Marshalthe provincial fire marshal’s office and your local fire service
Northwest TerritoriesNational Fire Code under the Fire Prevention Actthe provincial fire marshal’s office and your local fire service
NunavutNational Fire Code under the Fire Safety Actthe provincial fire marshal’s office and your local fire service

Frequently asked questions

Does my six-unit apartment building need a fire safety plan?

In most provinces, yes — residential buildings above a small threshold require one. Check with us; the threshold varies, but enforcement against small landlords is common because so few comply.

How long does approval take?

Typically 2–8 weeks depending on the fire department’s queue and revision rounds. Straightforward buildings with clean drawings approve fastest.

What is a fire safety plan box?

A locked box near the main entrance holding the approved plan and keys/fobs for fire department use. Several municipalities mandate them for larger buildings.

We have a plan from 2009. Is that a problem?

Almost certainly — staffing, systems and code expectations have changed. An outdated approved plan is a deficiency, and updating is far cheaper than starting from scratch.